The Power Supply is used for the operating voltage supply of the ISYGLT BUS components. When dimensioning the Power Supply, the maximum current values of the individual modules must be added. This is very easy to calculate via the parts list in the ProgramDesigner after the modules have been created.
Electrical Data
Operating voltage (primary) | 230V AC +/-10% 48-63Hz |
Output voltage | 24V-28V DC adjustable, tolerance +/- 3% |
Output current | 5.0A short-circuit proof, electronically protected |
Minimum load | 0 mA |
No-load power loss | 0.9W |
Residual ripple | 20 mVpp |
Connection | screw terminals 2.5mm² |
Operating temperature | -20...+40°C |
Storage temperature | -25...+70°C |
Humidity | 5...90% r.h. non-condensing |
Protection class | in non-installed state IP30 |
New
Sale
NT24V/5,0A-S
Article no.: 80030050
The Power Supply Unit is used to supply the ISYGLT BUS components with operating voltage.