I/O-04HD-230V-16A
Article no.: 80022464
-
kostenlose Anfrage / free request
from 1 € 0.00 € 0.00
The I/O module I/O-04HD-230V-16A is designed for applications where manual intervention is required or where the state of the relays must be maintained in the event of a BUS or power failure.
It is possible to switch 4 circuits with a maximum of 230V/16A. The phase position of the individual fuses is arbitrary. 4 optocoupler inputs 230V on a common counter potential are available as inputs.
All inputs and outputs in the module can be parameterised to various functions and the functions can be freely programmed via the ISYGLT ProgramDesigner software.
To protect the module from dust and unwanted operations, it is closed with a transparent lid. A screwdriver is required for manual operation.
Operating voltage | 16V to 35V DC resp. 16V to 27V AC |
Current consumption | 200mA at 24V DC |
Inputs | 4x 230V AC, input current per input 1.5mA at 230V |
Outputs |
4x relay contact max. switching voltage 440V AC max. switching current 20A >> (terminal max. 16A !) mech. life 1.000.000 cycles Load capacity: pure ohm's 16A incandescent lamps 3500W (max. 30.000 cycles) fluorescent lamps uncompensated 3500W (max. 30.000 switching cycles) fluorescent compensated 2500W/200uF (max. 30.000 switching cycles) high voltage halogen 3500W (max. 30.000 switching cycles) low voltage halogen via transformer 2000VA (max. 30.000 switching cycles) ECGs depending on manufacturer, switch-on current 100A < 20ms ! The inrush current of electronic ballasts is up to 100 times the rated current !! minimum contact load: 500mW, min. 10V, min. 5mA |
Subnet (RS-485) | max. 5.6V limitation by Z-diodes |
Connection | screw terminals 2.5mm² pluggable |
Operating temperature | -10...+50°C |
Storage temperature | -25...+70°C |
Humidity | 0...85 % r.h. non-condensing |
Protection class | when not installed IP30 |
8-pole DIP switch for setting the ISYGLT BUS address (0-127) is located under the cover of the module.
DIP-1 | Setting |
---|---|
OFF | BUS operation |
ON | Emergency operation (see parameterization options) |
LED | Designation | State | Meaning |
---|---|---|---|
red | POWER | Off | No operating voltage |
On | Operating voltage, no error | ||
yellow | BUS | Off / On | Error BUS |
blinking | Interference-free data transmission via the BUS line | ||
4x green | Output 1-4 | Off | Output inactive (parameterizable) |
On | Output active (parameterizable) | ||
4x yellow | Input 1-4 | Off | Input inactive |
On | Input active |
Article no.: 80022464